<Error>
<ErrorNumber>17743</ErrorNumber>
<ErrorFamily>Exposure Head</ErrorFamily>
<ErrorMessage>
HEAD: thermal head humidity alarm, &lt;humidity&gt; percent
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Thermal</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Every thirty seconds, the thermal head firmware reads the humidity sensor and
compares the reading to the threshhold configured by the head NVS parameter
humidity.  If the threshhold has been exceeded, the thermal head is shutdown
and any plot in progress is aborted.
</text></DescriptionText>
<DescriptionText><text>
Setting the head NVS parameter humidity to zero disables the humidity check.
</text></DescriptionText>
<DescriptionText><text>
The humidity sensor is only available on some heads.  Issue the command "head
version" and note the line "PHC hardware version".  If the "PHC hardware
version" &gt;= 3, the thermal head has a humidity sensor.
</text></DescriptionText>
<DescriptionText><text>
This error code applies to Thermal Head firmware version 1.30 and above.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Call service.
</text></DescriptionText>
</OperatorAction>
<Cause>
Verify the humidity of the environment local to the machine.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/head_cal_humidity.xml</LinkAddress><LinkTitle>NVS: head humidity</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:46 2008 PST
</Updated>
<Links>
</Links>
</Error>